Skip to the main content

We turn what you know about heat-loss calculations and MCS design into a design firm for heat-pump installers, with you as its partner.

You check, correct and sign each heat-pump design. Our technology finds the installers and builds every heat-loss calculation and design pack, and we find the clients and handle the billing and admin.

Earn an extra income as the partner in a heat-pump design firm, without the hassle of running one.

  • You pay nothing to join.

    We fund the build, the systems and the marketing.

  • You own real shares as a partner.

    You are a partner in the firm, not an employee.

  • You are paid for every design you sign.

    Each design reaches you already prepared.

  • No clients to find and no paperwork to fill in.

    Our technology finds the installers and builds every heat-loss calculation and design pack.

  • You choose your designs and your hours.

    Designs come in every week, and each one goes back to the installer within 48 hours.

  • You are the only design partner we work with for this firm in the UK.

Heat-pump grant applications are at a record high, and every job needs a design that most installers have no time to do.

Small installers and gas engineers moving into heat pumps are taking on more jobs than ever, and the design work lands on their evenings.

  • 1

    A record 8,150 households applied for a Boiler Upgrade Scheme grant in July 2026.

  • 2

    That was 53 percent more than the previous monthly record, set in November 2025.

  • 3

    The grant for oil-heated homes in England and Wales was raised by 20 percent, and the higher grant runs only until March 2027.

  • 4

    Since the scheme began, 38 percent of grants have gone to homes off the gas grid.

  • 5

    Installers say design and heat-loss work is office work that is not part of their day job.

Book 15 minutes with Adam

Installers need what only an experienced heat-pump designer knows: how to size a system right and get the paperwork through first time.

  • You know that standard surveys oversize, and in one trial they were accurate in only 30 percent of homes.

  • You know that oversizing is the costliest design error, named the biggest problem by around half of installers.

  • You know how to size the emitters and pipework so the heat pump runs at a low flow temperature.

  • You know that incomplete or misfiled paperwork delays a grant or gets it rejected, and what a design pack needs to pass.

Book 15 minutes with Adam

Your only job is the expert judgement, while we find the installers, prepare the work and run the firm.

You check, correct and sign each heat-pump design.

  • Check each room-by-room heat loss.
  • Correct the sizing, emitters and pipework where needed.
  • Sign each design within 48 hours.
  • Answer installers' questions on harder homes.

We do all the work of finding the installers and preparing every design.

  • Find small installers and gas engineers taking on heat pumps.
  • Take in each phone survey, photos and address.
  • Build the room-by-room heat loss to BS EN 12831.
  • Size the heat pump, emitters, pipework and cylinder.
  • Produce the MCS 031 estimate, noise check and design pack.
  • Run the firm's website, systems, billing and admin.

Our technology prepares every design, and you check it, sign it and follow it from one place.

  1. 1

    New designs arrive already prepared for your judgement.

    The technology finds the clients, gathers the documents and builds the evidence first.

    Your firm: new designs
    Example

    Arrived this week, already prepared

    • 14 Elm Road, 1930s semiLeeds. Solid walls, new loft insulation.Heat loss done
    • Rose Cottage, stone detachedCumbria. Oil boiler replacement.Design pack drafted
    • Flat 3, Harbour ViewPlymouth. Electric storage heaters.Survey data checked
    • The Old RectoryNorfolk. Listed, single glazing.Emitters sized
  2. 2

    Each design reaches you as a finished draft to check and sign.

    You make the call that needs an expert, and your signature sends it.

    For your review
    Example

    Draft prepared for you

    Design pack: 14 Elm Road

    Heat loss

    Room by room at minus 3 degrees. Total 6.8 kW, not the 11 kW on the survey.

    Emitters

    Five radiators upsized to run at a 45 degree flow. The rest stay.

    Pipework

    Microbore to two bedrooms replaced. Primary pipework sized for the flow rate.

  3. 3

    The client follows their design on their own status page, so nobody chases you for updates.

    Your firm: your design
    Example

    design for

    14 Elm Road

    1. Survey received

      Photos and room sizes

    2. Heat loss

      Room by room calculation

    3. Design checked

      Signed within 48 hours

    4. Install

      Installer booked

    5. Commissioned

      Grant claimed

  4. 4

    Your design list shows every design, its stage and what needs you next.

    Your designs
    Example
    ClientWhereStageNext
    • 14 Elm RoadLeedsDesign pack readySign the design0
    • The Old RectoryNorfolkEmitters sizedCheck the high loss rooms1
    • Rose CottageCumbriaDesign pack draftedDue back tomorrow2
    • Flat 3, Harbour ViewPlymouthSurvey checkedHeat loss next3
    • 22 Mill LaneDerbySignedInstall on Monday4

An installer sends a survey, the technology builds the design, you check and sign it, and the installer quotes and claims the grant.

  1. Step 1

    An installer sends a phone survey, photos and the address of a home.

    The client does this

    1
  2. Step 2

    The system builds the room-by-room heat loss to BS EN 12831.

    We do all this work for you

    2
  3. Step 3

    It sizes the heat pump, emitters, pipework and cylinder.

    We do all this work for you

    3
  4. Step 4

    It produces the MCS 031 performance estimate and the noise check.

    We do all this work for you

    4
  5. Step 5

    You check, correct and sign the design within 48 hours.

    You do this

    5
  6. Step 6

    The installer uses the pack for the quote, the MCS certificate and the grant claim.

    The client does this

    6
  7. Step 7

    We bill the installer and take in their next survey, and you are paid for every design you sign.

    We do all this work for you

    7
Adam, the founder of Ruskin Morris.

Ruskin Morris was founded by Adam, an AI researcher and entrepreneur who studied Computer Science and Philosophy at Oxford, has started companies in the GovTech and EdTech spaces, and has built businesses for experts including in the financial sector.

We named the company after John Ruskin and William Morris, two Victorian Britons who argued that skilled work deserves to be properly valued and properly paid. That is what we do for experts today.

Here are straight answers to the questions people ask us before they book a call.

Book 15 minutes with Adam
Is this a job?

No. You are a partner with real shares in the firm, not an employee, and you are paid for every design you sign.

Do I pay anything?

No. We fund the build, the systems and the marketing.

Who is this for?

Experienced heat-pump system designers, MCS technical managers and heating engineers with advanced design training in the UK.

Who holds the MCS certificate?

The installer's MCS certification covers the install, and you sign the design.

Does the firm work with one brand of heat pump?

No. The firm designs for any brand, per job, so installers are not tied to one manufacturer.

How am I paid?

Adam goes through the money on the call, and it is all written into the partnership agreement before you start.

Why isn't the firm named after me?

The firm has its own name so it can keep serving clients however much you choose to work. You are named on it as its partner.

Find out how what you know about heat-loss calculations and MCS design can become a firm with you as its partner.

Book 15 minutes with Adam